Sign In | Join Free | My infospaceinc.com |
|
Brand Name : Shenglin
Model Number : MD series
Certification : CE
Place of Origin : China
MOQ : 5 pcs
Price : 1550~7000USD
Payment Terms : T/T, Western Union
Supply Ability : 1000 PCS/month
Delivery Time : 15~20 days
Packaging Details : Plywood box and with dust/moisture-proof film
COP : 4
Compressor : Panasonic or Copeland brand
Application : Appartment, School, Hospital, Villa
Supply power : 380V/3PH/50Hz
Refrigerant : R22/R417A/R404A/R407C/R410A
Working ambient temperature : -15~45 ° C
Warranty : 1 Year
Installation : Freestanding
Heating capacity range : 15~84kW
Water outlet temp. : 55° C
Max water outlet temp. : 60° C
Remark : Can OEM
Evaporator : Fin type heat exchanger
Condenser : Coil type heat exchanger
Commercial Use Air Source Heat Pump
We are a professional heat exchanger, condenser, evaporator and heat pump manufacturer in China,which has more than 16 years experience in HVAC area. Our products have been exported to Europe, USA, Japan and Middle east etc.
Technical paramater:
Air source heat pump | MODEL | Unit | MD40D | ||
Average heating input power | KW | 3.78 | |||
Rated heating capacity | KW | 15 | |||
Hot water supply | L/h | 350 | |||
Rated heating input current | A | 9 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 55 | |||
Dimension | W*D*H | mm | 1120*490*1270 | ||
Packing size | W*D*H | mm | 1200*520*1425 | ||
Unit weight | KG | 160 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 4000L/h | |||
Water pressure down | Kpa | 55 | |||
Pipe size | DN | 25 | |||
Air source heat pump | MODEL | Unit | MD50D | ||
Average heating input power | KW | 4.6 | |||
Rated heating capacity | KW | 18.6 | |||
Hot water supply | L/h | 400 | |||
Rated heating input current | A | 9 | |||
Max outlet water temp | C | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 55 | |||
Dimension | W*D*H | mm | 1120*490*1270 | ||
Packing size | W*D*H | mm | 1200*520*1425 | ||
Unit weight | KG | 170 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 5000L/h | |||
Water pressure down | Kpa | 45 | |||
Pipe size | DN | 25 | |||
Article | Parameter | ||||
Air source heat pump | MODEL | Unit | MD60D | ||
Average heating input power | KW | 5.2 | |||
Rated heating capacity | KW | 21 | |||
Hot water supply | L/h | 500 | |||
Rated heating input current | A | 12 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380/50 | |||
Noise | Db(a) | 60 | |||
Dimension | W*D*H | mm | 1120*490*1270 | ||
Packing size | W*D*H | mm | 1200*520*1425 | ||
Unit weight | KG | 180 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 6000L/h | |||
Water pressure down | Kpa | 48 | |||
Pipe size | DN | 25 | |||
Air source heat pump | MODEL | Unit | MD100D | ||
Average heating input power | KW | 9.2 | |||
Rated heating capacity | KW | 36 | |||
Hot water supply | L/h | 800 | |||
Rated heating input current | A | 18 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 60 | |||
Dimension | W*D*H | mm | 1450×760×1060 | ||
Packing size | W*D*H | mm | 1520*800*1230 | ||
Unit weight | KG | 310 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 10000L/h | |||
Water pressure down | Kpa | 54 | |||
Pipe size | DN | 32 | |||
Air source heat pump | MODEL | Unit | MD150D | ||
Average heating input power | KW | 11 | |||
Rated heating capacity | KW | 42 | |||
Hot water supply | L/h | 1000 | |||
Rated heating input current | A | 24 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 60 | |||
Dimension | W*D*H | mm | 1450×760×1060 | ||
Packing size | W*D*H | mm | 1520*800*1230 | ||
Unit weight | KG | 340 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 12000L/h | |||
Water pressure down | Kpa | 54 | |||
Pipe size | DN | 32 | |||
Article | Parameter | ||||
Air source heat pump | MODEL | Unit | MD200D | ||
Average heating input power | KW | 19 | |||
Rated heating capacity | KW | 72 | |||
Hot water supply | L/h | 1600 | |||
Rated heating input current | A | 35 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 70 | |||
Dimension | W*D*H | mm | 2040×1100×2000 | ||
Packing size | W*D*H | mm | 2080×1150×2130 | ||
Unit weight | KG | 650 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 20000L/h | |||
Water pressure down | Kpa | 60 | |||
Pipe size | DN | 50 | |||
Air source heat pump | MODEL | Unit | MD300D | ||
Average heating input power | KW | 22 | |||
Rated heating capacity | KW | 84 | |||
Hot water supply | L/h | 2000 | |||
Rated heating input current | A | 40 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 70 | |||
Dimension | W*D*H | mm | 2040×1100×2000 | ||
Packing size | W*D*H | mm | 2080×1150×2130 | ||
Unit weight | KG | 750 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 25000L/h | |||
Water pressure down | Kpa | 60 | |||
Pipe size | DN | 50 |
Packing:
![]() | ![]() |
Simple installation diagram for air source:
![]() |
MD150D Air Source Heat Pump Images |